A joint SickKids-UHN facility providing academic and corporate clients with state-of-the-art analytical flow cytometers and high-speed cell sorting, as well as training, education and consultation services. Located in the Peter Gilgan Centre for Research and Learning (PGCRL) and the Princess Margaret Cancer Research Tower (PMCRT).

Services
  • Cell sorting
  • Analytical Flow Cytometry
  • Automated Magnetic Cell Separation
  • Consultation
  • Data analysis
  • Training
Available Equipment
  • Analytical Cytometers

    PMCRT

    • One BD Fortessa UVBGR, with HTS and 18 colors (4UV, 6V, 2B, 3G, 3R); located in room 2-203
    • Two BD Symphony A3 UVBYR, with HTS and 28 colors (7UV, 8V, 5B, 5Y, 3R); located in room 2-504

    PGCRL

    • One LSRII GC VBR, with 12 colors (3V, 6B, 3R); located in room 18.9430
    • One BD Fortessa UVBGR, with HTS and 18 colors (3UV, 6V, 2B, 3G, 3R); located in room 18.9430
    • One BD Symphony A3 UVBYR, with HTS and 28 colors (7UV, 8V, 5B, 5Y, 3R); located in room 18.9430

    More information is available here.

  • Cell Sorters with a Bio-safety Cabinet

    PMCRT

    • One BD Aria CFI VBYR, with 18 colors (6V, 6B, 3Y, 3R); located in room 2-203
    • Two BD Aria Fusion A VBGR, with colors (6V, 2B, 5G, 3R); located in rooms 2-203 and 2-504
    • One BD Symphony S6 A UVBYR, with 30 colors (8UV, 8V, 6B, 5Y, 3R); located in room 2-203

    PGCRL

    • Sony MA900 VBYR, 12 colors (6B/YG: 488nm (blue) and 561nm (yellow-green): co-linear; 6V/R: 405nm (violet) and 638nm (red): co-linear); located in room 18.9430
    • Sony SH800 VBR, 6 colors (co-linear lasers, VBR); located in room 18.9430

    More information is available here.

  • Magnetic Cell Separator

    PMCRT

    • One Miltenyi Biotec AutoMACS Pro magnetic cell separator; located in room 2-504

    More information is available here.

Using the Facility

General policies

  • Open for registration to researchers at UHN, SickKids, the University of Toronto, and all external academic and non-academic investigators
  • Please see website for specific instrument locations
  • First-come, first-serve priority system, with booking required

Training

  • To use any of the analytical cytometers or automated magnetic cell separators, users must receive training from FCF staff

Sample Preparation

Usage Arrangements

 

Contacts

PMCRT

  • Office: 416-581-7643
  • Labs: 416-581-7654 or 416-581-7610

PGCRL

  • Office: 416-813-7654 (ext. 309086)
  • Lab: 416-813-7654 (ext. 309103)

For sorting questions, please contact Dr. Sherry Zhao.

For analytical questions, please contact Dr. Emily Reddy.

For financial questions, please contact Dr. John Moniakis.

A joint SickKids-UHN facility providing academic and corporate clients with state-of-the-art analytical flow cytometers and high-speed cell sorting, as well as training, education and consultation services. Located in the Peter Gilgan Centre for Research and Learning (PGCRL) and the Princess Margaret Cancer Research Tower (PMCRT).

Available Equipment
  • Analytical Cytometers

    PMCRT

    • One BD Fortessa UVBGR, with HTS and 18 colors (4UV, 6V, 2B, 3G, 3R); located in room 2-203
    • Two BD Symphony A3 UVBYR, with HTS and 28 colors (7UV, 8V, 5B, 5Y, 3R); located in room 2-504

    PGCRL

    • One LSRII GC VBR, with 12 colors (3V, 6B, 3R); located in room 18.9430
    • One BD Fortessa UVBGR, with HTS and 18 colors (3UV, 6V, 2B, 3G, 3R); located in room 18.9430
    • One BD Symphony A3 UVBYR, with HTS and 28 colors (7UV, 8V, 5B, 5Y, 3R); located in room 18.9430

    More information is available here.

  • Cell Sorters with a Bio-safety Cabinet

    PMCRT

    • One BD Aria CFI VBYR, with 18 colors (6V, 6B, 3Y, 3R); located in room 2-203
    • Two BD Aria Fusion A VBGR, with colors (6V, 2B, 5G, 3R); located in rooms 2-203 and 2-504
    • One BD Symphony S6 A UVBYR, with 30 colors (8UV, 8V, 6B, 5Y, 3R); located in room 2-203

    PGCRL

    • Sony MA900 VBYR, 12 colors (6B/YG: 488nm (blue) and 561nm (yellow-green): co-linear; 6V/R: 405nm (violet) and 638nm (red): co-linear); located in room 18.9430
    • Sony SH800 VBR, 6 colors (co-linear lasers, VBR); located in room 18.9430

    More information is available here.

  • Magnetic Cell Separator

    PMCRT

    • One Miltenyi Biotec AutoMACS Pro magnetic cell separator; located in room 2-504

    More information is available here.

Contacts

PMCRT

  • Office: 416-581-7643
  • Labs: 416-581-7654 or 416-581-7610

PGCRL

  • Office: 416-813-7654 (ext. 309086)
  • Lab: 416-813-7654 (ext. 309103)

For sorting questions, please contact Dr. Sherry Zhao.

For analytical questions, please contact Dr. Emily Reddy.

For financial questions, please contact Dr. John Moniakis.

Services
  • Cell sorting
  • Analytical Flow Cytometry
  • Automated Magnetic Cell Separation
  • Consultation
  • Data analysis
  • Training
Using the Facility

General policies

  • Open for registration to researchers at UHN, SickKids, the University of Toronto, and all external academic and non-academic investigators
  • Please see website for specific instrument locations
  • First-come, first-serve priority system, with booking required

Training

  • To use any of the analytical cytometers or automated magnetic cell separators, users must receive training from FCF staff

Sample Preparation

Usage Arrangements